You don't need to move anything. You only need to unset specific checkboxes in RGN_Tool and save the result as RGN file.
That "know what you're doing" warning is ok to ignore.
I can make RGN files for you tomorrow if you're too afraid of it.
Last edited by kunix; 3rd June 2014 at 10:40 PM.
I'm not afraid, RGN Tool just doesn't do what I thought it would do.
If I just uncheck the boot.bin checkbox, it says "Section 1 must be enabled. Normally it should contain section '0800' boot.bin." So I *have* to move the fw_all.bin segment.
I think you can restart updater.exe after flashing each RGN.
Latest update:
1) I flashed with boot.bin only fw. "Update successful" - Cannot flash again with restarting to pre-boot mode.
2) Flashed with fw_all.bin only fw "Update successful" - I can immediately flash boot.bin without restarting.
3) Flashed with boot.bin fw "Update successful" - Cannot flash again with restarting to pre-boot mode.
4) Restarted - it's back to "Loading maps..." hang. Woohoo.
5) Flashed with 0827 cure firmware - IOU_UTILITIES error
6) Restarted - "Loading maps..." hang
It doesn't show up in RMPrepUSB tool during any of these steps however.
I've repeated the above steps several times, and I'm at step 3 now.
What's next?
'Thanking Posts' are banned. To thank someone, and/or to see hidden links and content, use the [Only registered and activated users can see links. ] button below left of the helpful post then refresh your browser [F5 key]. 'Thanking Posts' are banned.
Please don't spam. Posts serving no purpose other than to thank or to ask about hidden links are trashed or deleted, it's GPSPower's policy. Please don't spam.
[Only registered and activated users can see links. ] should make their first post as a new Intro Thread in [Only registered and activated users can see links. ].
pgardella, can you confirm that flashing RGN with original fw_all.bin only completes successfully, but flashing RGN with the same fw_all.bin, but patched by GarminCure3's CURE option, completes with IOU_UTILITIES error?
Neil , I think we can do this already. But there could be a bigger problem...
I can flash with boot.bin-only RGN successfully. I can flash with fw_all.bin-only RGN successfully. But if I flash with the original (boot.bin & fw_all.bin) run through CURE fails with the IOU_UTILITIES error. I have not tried flashing with fw_all.bin run through CURE. I don't know enough about the firmware to know if this would work or break something worse.
Last edited by pgardella; 4th June 2014 at 12:32 PM.
I promise that flashing GarminCure3-ed firmware without boot.bin (fw_all.bin only) won't make your device feel worse.
Please, try it.
Perfect! Its now working with CURE and mounting the drive. Any thoughts on which file might be the problem one? Or do you suggest wiping it and starting over?