    Please Help

    I have US Oregon 550 which I tried to patch its firmware with Korean firmware and bricked it.

    1. Bricked US Oregon 550 HWID 0896 S/W ver 660

    2. I followed RGN_tools to change US to Korean. But Its instruction gave me "software missing error" and didn't work.
    So I changed both boot.bin and fw_all.bin to Korean HWID 1209 sw 280.

    3. Device now just boots into the software missing error then red screen, no filesyetem access to internl memory

    4. No, PC does not see the device anymore

    5. Downloaded GCD files from garmin download, Oregon550,Korea_GCDfile__280.gcd and Oregonx50_WebUpdater__660.gcd

    Ran GarminCure and created cure file with ver 660
    Applied using updater and updater gave me an error "invalid device"
    The device is NOT detected by the PC. Garmin Webupdater see the device as Korean 550 and gives me errors

    6. Yes, Garmin driver's are installed (as part of Garmin express)

    7. HWID is 1209 (changed by boot.bin patch, original is 0896)

    8. Yes, tried that (Pl. see #5 above)

    9. Yes, In preboot mode I can see System (and loading when applying the update using Updater). The screen is turn off with updater saying invalid device
    (my guess is cured firmware of US doens't match with current HWID 1209. Is there anyway to change HWID back to original??

    10. Sorry No, my bad, No NV backup

    11. Waiting for your response. If I can change HWID 1209(korean 550) back to original 0896(US 550), I guess cure and updater can work.

    Is there anyway to change HWID 1209 back to original 0869??

    Thank you in advance.

  2.    Advertissements


  3. #2
    Important User IMPORTANT! If you want HELP in case of a bricked Garmin device, please follow this
    IMPORTANT! If you want HELP in case of a bricked Garmin device, please follow thisIMPORTANT! If you want HELP in case of a bricked Garmin device, please follow this
    Butters's Avatar
    Join Date
    Jul 2017
    Location
    CA
    Posts
    1,466
    Rep Power
    1058

    Default

    Quote Originally Posted by sbihue View Post
    Thanks Butters. Unfortunately, No, I don't have any backup of either the NV or the FileSystem. All I have is the original GarminDevice.xml

    Update:
    .......................
    Get content from Garmin
    7. Used Garmin Connect to update the Device with all pending files (maps, other files). had to do this a few times as Garmin Connect would not identify the device and crash when starting the update
    ......................
    If you'd put the old XML into a Garmin root folder before you connected to Garmin Express it probably wouldn't have crashed. I'd guess you finally rebooted the device which re-created the GarminDevice.xml so that GE could see it properly. You wouldn't have received another basemap from GE and will need to load one manually to ensure proper operation: [Only registered and activated users can see links. ].

    Quote Originally Posted by shawn_pa View Post
    Please Help

    I have US Oregon 550 which I tried to patch its firmware with Korean firmware and bricked it.

    1. Bricked US Oregon 550 HWID 0896 S/W ver 660

    2. I followed RGN_tools to change US to Korean. But Its instruction gave me "software missing error" and didn't work.
    So I changed both boot.bin and fw_all.bin to Korean HWID 1209 sw 280.

    3. Device now just boots into the software missing error then red screen, no filesyetem access to internl memory

    4. No, PC does not see the device anymore

    5. Downloaded GCD files from garmin download, Oregon550,Korea_GCDfile__280.gcd and Oregonx50_WebUpdater__660.gcd

    Ran GarminCure and created cure file with ver 660
    Applied using updater and updater gave me an error "invalid device"
    The device is NOT detected by the PC. Garmin Webupdater see the device as Korean 550 and gives me errors

    6. Yes, Garmin driver's are installed (as part of Garmin express)

    7. HWID is 1209 (changed by boot.bin patch, original is 0896)

    8. Yes, tried that (Pl. see #5 above)

    9. Yes, In preboot mode I can see System (and loading when applying the update using Updater). The screen is turn off with updater saying invalid device
    (my guess is cured firmware of US doens't match with current HWID 1209. Is there anyway to change HWID back to original??

    10. Sorry No, my bad, No NV backup

    11. Waiting for your response. If I can change HWID 1209(korean 550) back to original 0896(US 550), I guess cure and updater can work.

    Is there anyway to change HWID 1209 back to original 0869??

    Thank you in advance.
    Cure firmware won't help because it's used only to enable Mass Storage Mode so that any corrupt file stopping the device from booting can be removed or to allow a re-format. Your problem is that the Korean firmware has completely overwritten the device's regions and there is now incompatibility, perhaps due to differing hardware. Luckily you have preboot available otherwise it might be completely dead. Try to flash the original (unpatched) US/EU firmware in preboot as an RGN with HWID 0896. Don't use conventional safe-naming for the RGN file, that can't work. Name the file OUT.RGN to try forcing the flash.

    Note: I can't say that will work for sure but if the device was mine i'd do it for sure, it's at your risk if you try it but it can hardly make things worse i guess.

  4. #3
    Junior Member
    Join Date
    Dec 2007
    Location
    Alaska
    Posts
    5
    Rep Power
    0

    Default

    Quote Originally Posted by Butters View Post
    If you'd put the old XML into a Garmin root folder before you connected to Garmin Express it probably wouldn't have crashed. I'd guess you finally rebooted the device which re-created the GarminDevice.xml so that GE could see it properly. You wouldn't have received another basemap from GE and will need to load one manually to ensure proper operation: [Only registered and activated users can see links. ].
    Good to know. Updated my notes for future recovery, if and when needed. BTW, I backed up all regions, including 41
    Last edited by sbihue; 28th August 2018 at 09:55 PM.

 

 